LE4S Output Operation Mode
Mode
Time chart
[
]
INT
INT
RELAY OUT
Setting time
UP
Setting time
Interval
DOWN
1. Output will be ON when START signal is ON at status of power on and Timing operation starts.
2. Output will be OFF when timing operation is progressed up to the setting time. Display value will be HOLD.
3. When RESET signal is ON, display value and output will be reset. (① position)
T > Ta
4. If RESET signal is OFF when START signal is ON,"STEP 1" will be restarted.
5. When START signal is OFF, display value and output will be reset. (② position)
[
]
INt1
INTⅠ
RELAY OUT
Setting time
UP
Setting time
Interval 1
DOWN
1. Output will be ON when START signal is ON at status of power on and Timing operation starts.
2. Output will be OFF when timing operation is progressed up to the setting time. Display value will be HOLD.
3. Even though START signal is applied repeatedly, only the initial signal is recognized. (① position)
4. If START signal is ON after timing operation is progressed up to the setting time, Output will be ON and setting
T > Ta
time will be reset and then timing setting starts.
5. When RESET signal is ON, display value and output will be reset. (② position)
[
NFD
]
ON OFF D
RELAY OUT
Setting time
UP
Setting time
DOWN
ON-OFF Delay
1. If START signal is ON when power is on, Output will be ON when timing operation is progressed up to the Ton
setting time (On-Delay). IF START signal is OFF, output will be ON when timing operation is progressed up to
the Toff setting time (OFF-Delay).
2. If START signal is applied repeatedly, output is ON and display value will be reset. (① position)
3. When RESET signal is ON, display value and output will be reset. When RESET signal is OFF while START
T > Ta
signal is ON, it will be operating as On-Delay. (② position)
4. It is able to set each Toff time and Ton time separately.
[
NFd1
]
ON OFF DⅠ
RELAY OUT
Setting time
UP
Setting time
DOWN
ON-OFF Delay 1
1. If START signal is ON when power is on, timing operation starts. Output will be ON when timing operation is
progressed up to the Ton setting time (On-Delay). IF START signal is OFF, output will be ON when timing
operation is progressed up to the Toff setting time (OFF-Delay).
2. Output will be ON when START signal is ON and goes OFF during setting time and display value will be reset. (① position)
3. Output will be OFF when START signal is OFF and goes ON during setting time and display value will be reset. (① position)
4. When RESET signal is ON, display value and output will be reset. When RESET signal is OFF while START
T > Ta
signal is ON, it will be operating as On-Delay. (② position)
5. It is able to set each Toff time and Ton time separately.
[
]
OFD
OFF D
RELAY OUT
Setting time
UP
OFF Delay
Setting time
DOWN
1. If START signal is ON when power is on, output will be ON.
2. When START signal is OFF, timing operation starts. Output will be OFF when timing operation is progressed up
T > Ta
to the setting time. Display value will be HOLD.
3. When RESET signal is ON, display value and output will be reset.
※ Initial status: UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
T
POWER
START
RESET
0
0
T
Ta
POWER
START
①
RESET
0
0
Ton
Toff
Ta Ta
POWER
START
RESET
ON Delay
OFF Delay
0
ON Delay
OFF Delay
0
Ton
Toff
Ta Ta
POWER
START
RESET
ON Delay
OFF Delay
0
ON Delay
OFF Delay
0
Ta
T
POWER
START
RESET
0
0
LCD Display Timer
T
Ta
T
②
①
T
T
②
Toff
Ta
Ton
Ta
①
②
Toff
Ta
Ton
Ta
①
②
Ta
Ta
T = Setting time, T > Ta
Operation
POWER
START
T
RELAY
OUT
T = set time
T
POWER
START
T
RELAY
OUT
T = set time
Ton
Toff
POWER
START
Ton
RELAY
OUT
Ton, Toff = set time
Ton
Toff
POWER
START
Ton
RELAY
OUT
Ton, Toff = set time
T
POWER
START
RELAY
OUT
T = set time
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
T
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Toff
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
Toff
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
T
Field Network
Devices
N-35