Troubleshooting

If the flood sensor does not close the valve, check that the sensor has power and batteries and/or AC adaptor are
installed correctly .
If the batteries have power and the wireless sensor still does not make the valve close, physically remove it from its
installed location and place it next to the WaterCop
to the WaterCop
valve, but not when it is installed in a remote location, try moving the sensor to a different position or
®
try a different wireless sensor . Some possible causes of signal reduction are steel construction, foil-backed insulation
or other large metallic barriers . You may also use a range enhancing repeater (WPR - sold separately) to extend the
effective range of the wireless signals.
If the unit still does not function properly, check the digital code settings (see instructions for changing digital codes) .
If the code matches the code on the WaterCop

Installation of Flood Sensor

Once testing is complete, finish installation of the flood sensors by unwinding the cord and placing the sensor probe on
the floor at the lowest point (where water would naturally collect) in the area to be monitored . Be sure that the sensor is
placed FLAT on the floor so water can be detected as soon as it begins to accumulate. The sensor may be secured to the
floor with adhesive dots (included), taking care that the metal probes are
not covered . Verify that the transmitter and wire are clear of doors,
drawers, sharp edges, or other hazards that may cause damage .
Unplug the WaterCop
®
The WaterCop
can now be installed.
®
Prior to installation, read all warnings and precautions carefully .
Installation Procedure
Check the contents of the carton with the products listed on the
carton label . The shipping package should contain the following:
1 ea . WaterCop
with power adaptor (20' cord)
®
1 ea . Owner's Manual/Installation Guide
Note: The package may contain sensors if purchased as part of kit .
Read Operating Instructions before any installation is attempted . All
sections of this Owner's Manual/Installation Guide should be read
and completely understood .
Review Location and Type of Main Supply Line
The main supply line should enter the house in either the basement
or a crawl space beneath the first floor . The water main shut-off
valve is usually located near where the line comes through the
basement wall or just after the water line enters the living area from
the crawl space . In apartments, townhouses, and manufactured
housing constructions the water main shut-off valve can usually
be found in close proximity to the water heater installation . The
WaterCop
valve should be installed in the main water line just
®
downstream from the main shut-off valve in your home . The water
supply must be shut off prior to installation of the WaterCop
DynaQuip Controls • 10 Harris Industrial Park • St. Clair, MO 63077
Tel. 800-545-3636 • Fax. 636-629-5528 • www.watercop.com
valve, and it still does not function properly, replace the sensor .
®
after the testing is complete.
valve . Repeat test . If the sensor operates properly when it is closer
®
Water level
.
®
Sensor placed at a low spot
in the path of water flow where
it will make contact with sensor .