Autonics BD Series Руководство - Страница 13

Просмотреть онлайн или скачать pdf Руководство для Датчики безопасности Autonics BD Series. Autonics BD Series 14 страниц. Laser displacement sensors amplifier unit
Также для Autonics BD Series: Руководство по эксплуатации (6 страниц), Руководство по эксплуатации (5 страниц), Руководство по эксплуатации (3 страниц)

Autonics BD Series Руководство
BD Series

▣ Cautions during Use

1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. The power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Do not install where strong magnetic or electric field exist. Otherwise, the resolution may be adversely affected.
4. Mutual optical interference between laser sensors and photoelectric sensors may result in malfunction.
5. Mutual optical interference between laser sensors may result in malfunction.
6. When connecting DC relay or other inductive load to the output, remove surge by using diode or varistor.
7. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
[Amplifier unit]
8. For the optimized performance, it is recommended to measure after 30 minute from supplying power. [Amplifier unit]
9. Since external disturbance light (sunlight, fluorescent lighting, etc.) can cause product malfunction, use the product with a
light shield or slit. [Sensor head]
10. When detecting with the maximum sensitivity, an error may occur depending on each characteristic deviation.
11. This unit may be used in the following environments.
①Indoors/Outdoors (in the environment condition rated in 'Specifications')
②Altitude max. 2,000m
③Pollution degree 2
④Installation category II
E-18