List of Algorithms:
1. 14.8v Constant Volatage (absorption) 13.5v float. C.V. time from 60min to 600 min. Boost multiplier 10.
2. 14.8v Constant Volatage (absorption) 13.3v float. C.V. time from 60min to 600 min. Boost multiplier 10.
3. 14.6v Constant Volatage (absorption) 13.5v float. C.V. time from 60min to 600 min. Boost multiplier 10.
4. 14.6v Constant Volatage (absorption) 13.3v float. C.V. time from 60min to 600 min. Boost multiplier 10.
5. 14.4v Constant Volatage (absorption) 13.5v float. C.V. time from 60min to 600 min. Boost multiplier 8.
6. 14.4v Constant Volatage (absorption) 13.3v float . C.V. time from 60min to 600 min. Boost multiplier 8.
7. 14.2v Constant Volatage (absorption) 13.8v float . C.V. time from 60min to 600 min. Boost multiplier 5.
8. 14.8v Constant Volatage (absorption) 15.3v Equalization 13.3 volt float. . Equalization time is 240 min.
9. LFP Constant Volatage 14.5 volts 30min then 13.4 volt rest voltage. C.V. time 20min.
0. LFP Constant Strait 13.4 volt cruiser voltage.