Autool CT-200 Руководство - Страница 9
Просмотреть онлайн или скачать pdf Руководство для Сервисное оборудование Autool CT-200. Autool CT-200 18 страниц. Injector cleaner & tester
Также для Autool CT-200: Руководство пользователя (14 страниц), Руководство пользователя (14 страниц)
![Autool CT-200 Руководство](/uploads/products/server2/1946013/1946013.jpg)
2) Press Left or Right Arrow key to set up injecting time (account time)
3) The next steps are the same as what listed in 02 Idle Speed Test.
NOTE:
To simulate the injecting condition after working for a certain times in Idle
speed
09 Medium Speed Spray Value Test
1) Press Left or Right Arrow key to select Medium Spray Value Test, then
press RUN key.
2) The next steps are the same as what listed in 08 Idling Spray Value Test.
10 High Speed Spray Value Test
1) Press Left or Right Arrow key to select Medium Spray Value Test, then
press RUN key.
2) The next steps are the same as what listed in 08 Idling Spray Value Test.
NOTE:
1. Check the deviation of the spray value: test the spray value in different
rpm, check the spray value in different measuring cylinder, the
deviation should not exceed 2% or refer the specification of the injector.
2. Leakage test: leakage should not occur within 1 minute under 0.3MPA
system pressure.
3.3 Reverse Flushing
The flush fluid go into the injector through its outlet and go out through
its inlet, so that it can clean the filth inside, which can not be cleaned by
normal way.
- - 9 - -