Factory Settings
The APCECOD comes pre-programmed with factory settings.
These settings may be adjusted by the user. For best results
verify any changes after adjusting settings. The controller can be
easily reset to factory settings. (see below)
CO2 PPM setting
CO2 dead-band
Calibrate CO2 PPM
CO2 Function
CO2 Mode
Fuzzy Logic
Reset Factory Settings - Press and hold the Enter / Reset and
down buttons for 3 seconds. The display will read f.Set. Press the
Enter/reset button again to restore the factory default settings.
The unit will go through a self-test and when the factory reset is
complete, the unit will say
Overview
The individual push-
buttons on the
APCECOD makes
changing settings EASY.
* Press a button, the
display shows the current
setting.
* To change the settings,
use the UP and DOWN
buttons.
* Then press ENTER to
accept the new setting.
1250 PPM
50 PPM
380 PPM
Daytime
Increase
(Off) Generator mode
donE.
APCECOD