If the CPL turns constant red, the output is muted, and the -4dB signal
LED is on, then the amplifier has gone into maximum current protection.
NOTE
This situation is caused by an excessive input signal and is not due to a
short circuit. Turn down the input signal to avoid or remedy this situation.
Temperature protection
Thermal measurement points are provided on each output channel as well as on the
power supply. These indicators will, if the pre-specified temperature level is
exceeded, give a high temperature warning. This warning condition is indicated by
a flashing TEM LED on the front panel.
As the amplifier approaches a thermal protection threshold, the warning LED
sequence will start with short " on-time" bursts. If the amplifier continues to
overheat and approaches the temperature limit, the flashing sequence will be
defined by longer and longer on-time bursts until the protection mode is activated.
If the temperature becomes too high to continue safe operation, the overheated
output channel(s) will be muted until the temperature returns to an acceptable level.
Fully active temperature protection (with muting) is indicated by a constantly
illuminated TEM LED. Temperature measurements will continue at 6 second
intervals. The output will un-mute when the channel or power supply returns to a
safe operating temperature.
Power Average Limiter (PAL)
The Power Average Limiter (PAL) controls the current-drawing relationship
between the power supply and the mains inlet. PAL limits the maximum average
power consumption according to the power supply capabilities, ensuring that the
PSU will not overload. In addition, in the larger models that potentially could pull
more current from the mains than the mains fuses are specified to handle (more
than 16A), PAL limits the amplifier's maximum current draw to prevent blowing the
mains fuse.
Soft-Start
High powered amplifiers with inadequate inrush limiting can pull considerable
current from the mains at turn-on. This can result in tripping of fast-acting mains
breakers. Such is not the case with TD-10000Q amplifier. The TD-10000Q amplifier
has very low inrush power as the capacitors are charged slowly and in a controlled
manner ensuring that breakers will not trip.