Emerson APOLLO CF3900AB01 Руководство пользователя - Страница 12

Просмотреть онлайн или скачать pdf Руководство пользователя для Вентилятор Emerson APOLLO CF3900AB01. Emerson APOLLO CF3900AB01 13 страниц. 52" apollo series

Emerson APOLLO CF3900AB01 Руководство пользователя
!
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
2. Fan sounds noisy.
3. Fan wobbles
excessively.
Printed in Taiwan 04/03
Part No. F40BP72340003
Trouble Shooting
PROBABLE CAUSE
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Reversing switch in neutral position.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Screws securing fan blade flanges to motor hub
are loose.
4. Switch housing binding against blade hub.
5. Wire connectors inside switch housing rattling.
6. Screws holding blades to flanges are loose.
1. Setscrew in motor coupling is loose.
2. Setscrew in hanger ball/downrod assembly is
loose.
3. Screws securing fan blade flanges to motor hub
are loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
6. Fan blades out of balance.
Air Comfort Products
DIVISION OF EMERSON COMPANY
8100 W. Florissant ¥ St. Louis, MO 63136
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch
wire connections in the switch housing.
WARNING: Make sure main power is turned off.
!
3. Make sure reversing switch position is all the way
to one side.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure the screws which attach
the fan flanges to the motor hub are tight.
4. Check to make sure that the switch housing
does not bind against the blade hub.
5. Check to make sure wire connectors in
switch housing are not rattling against each
other or against the interior wall of the switch
housing.
6. Tighten screws securely.
WARNING: Make sure main power is turned off.
!
1. Tighten the setscrew in the motor coupling.
2. Tighten the setscrew in the hanger ball/downrod
assembly.
3. Check to be sure screws which attach the fan blade
flanges to the motor hub are tight.
4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor hub. If flanges are
seated incorrectly, loosen the flange screws and
retighten
5. Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
Form No BP7234-3