STEP 5: GAS CONVERSION
Verify the type of gas supplied to the location. The
cooktop is shipped from the factory set up and
adjusted for natural gas. The unit can be readily
converted to LP as described below.
Natural Gas R equirements:
Connection: 1/2" N.P.T.
Pressure: 6" to 14" Water Column
A manual shut off valve must be installed before the
regulator.
LP Gas R equirements:
Pressure: 11" to 14" Water Column
A regulator is required at the LP source to provide a
maximum of 14" W.C. to the cooktop regulator.
LP CONVERSION:
If propane is desired you must obtain a conversion
kit from the factory for more information on type of
Call Parts and Service
conversion kit needed.
(888) 281-5698
HOOK UP:
Make sure the gas supply is turned off at the wall
valve before connecting the appliance. All gas sup-
ply connections should be made by a qualified tech-
nician and in accordance with local codes or ordi-
nances. In the absence of a local code, the installa-
tion must conform to the National Fuel Gas Code
ANSI 223.1-1984.
Install the 1/2" coupling to the gas inlet at the left
rear corner of the unit. Next, install the 1/2" close
nipple and regulator (See Fig.11). When installing
the regulator, be sure to have the arrow on the reg-
ulator body pointing towards the cooktop inlet.
Only use sealant which is resistant to the actions of
LP. gases.
To operate, push and turn the burner control knob
to the lite position. The gas flowing to the pilot
burner will be ignited by the electric spark igniter.
The audible clicking signal is an indication that the
igniter is functioning. The appliance is equipped
with a safety valve which will take about 30 seconds
to heat up before allowing the main burner to come
on, once ignited rotate the dial to the desired set-
ting.
GAS REQUIREMENTS
CAUTION:
The appliance must be isolated from the buildings-
gas supply piping system by closing its individual
manual shut-off valve during any pressure testing of
the gas supply piping system at test pressure equal
to or less than 1/2 psig (3.5 kPa.).
When checking the cooktop manifold gas pressure,
the inlet pressure to the regulator should be at least
6.0" W.C. for natural gas or 11.0" for LP.
7