The appliance has a thermostat which, when installed as indicated in paragraph 5.5, stops ice
production when the ice accumulated in the bin reaches the probe connected to the thermostat. When
ice is taken from the bin, the thermostat will automatically reactivate ice-cube production, thus creating a
new supply of ice.
Some models are fitted with a safety pressure switch that stops ice production in the event of a
malfunction of the cooling circuit; to restart the appliance, firmly press the reset button. If the fault still
persists, turn off the electric power source by means of the switch (6 in Fig. 4) fitted during the
installation phase, pull out the plug (if any) from its socket, turn off the water supply tap(s) (7 in Fig. 4),
and contact the nearest Authorized Technical Service Centre.
NOTE FOR MODELS WITH DAILY PRODUCTION OF 300 kg (Fig. 10):
The appliance is equipped with a safety minimum pressure switch that stops production in the event of a
malfunction of the cooling circuit; to restart the appliance, firmly press the reset button. If the fault still
persists, turn off the electric power source by means of the switch (6 in Fig. 4) fitted during the
installation phase, pull out the plug (if any) from its socket, turn off the water supply tap(s) (7 in Fig. 4),
and contact the nearest Authorized Technical Service Centre.
9.1 CLEANING THE FILTER OF WATER SUPPLY SOLENOID VALVE (Fig. 11)
‼
At least every two months, clean the filter (17) located on the water inlet solenoid valve, proceeding
as follows:
• switch off the electric power supply by means of the switch (6 in Fig. 4), fitted during installation,
and disconnect the plug of the appliance from its socket (if any)
• shut off the water supply by turning the tap (7 in Fig. 4) fitted during installation
• unscrew the threaded ring nut (12 in Fig. 5) of the water feed hose, located at the outlet of the solenoid
valve at the rear of the appliance
• using a pair of pliers, remove the filter (17) from its seat without damaging the water feed pipe
connector
• place the filter under a strong jet of water to remove residue, but replace the filter if it is excessively
dirty
NOTE FOR WATER-COOLED MODELS:
Repeat the operations described above for the cooling water solenoid valve.
After having carried out the cleaning operations, refit the filter(s) and hose pipe(s), taking the necessary
precautions described earlier in the manual.
When the operations have terminated, turn on both the electricity supply and water supply.
9.2 AIR-COOLED MODELS
For air-cooled models, it is very important to keep the finned condenser and its external filter (if any)
clean.
Have the finned condenser cleaned at least once every two months by an Authorized Technical Service
Centre, which can include this operation in the scheduled maintenance programme.
The external filter must be cleaned at least once a month, as follows:
MODELS WITH DAILY PRODUCTION OF 155 kg (Fig. 12):
•
• switch off appliance and cut off power supply with the switch (6 in Fig. 4) fitted at the installation
stage
• unscrew knobs that hold filter in place
• remove filter and keep it at a distance from the appliance
• remove dust from filter by blowing with compressed air
• replace filter in its seat and secure with knobs
8 OPERATION
9 MAINTENANCE F