IMPORTANT:
Disconnect the range and the individual shut-off valve from the gas supply piping system
during any pressure testing of that system at test pressures greater than 1/2 psig. Isolate
the range from the gas supply piping system by closing the individual manual shut-off
valve to the range during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig.
Connection: 1/2" N.P.T. - minimum 5/8" dia. metal flex line.
NOTE: Gas conversion should be done before pushing the range into the cabinet.
STEP 2
REPLACE COOKTOP BURNER ORIFICES AND VALVE BYPASS JETS
To replace cooktop burner orifices:
1. Remove the grates from the cooktop.
2. Remove burner caps and brass port rings (refer to diagram below).
3. Unscrew the brass nuts using a 1-1/16" socket or adjustable wrench and lift the simmer rings from the
burner bases.
4. Unscrew the brass venturis from the burner bases using a 25/32" socket.
5. Lift each burner base and disconnect the push-on wire
terminal from the spark electrode. Place the burner
base assembly in a safe place.
6. Remove the black porcelain plates under each burner
base to allow access to the orifice holders below the
cooktop panel.
7. Unscrew the orifices using an appropriately sized
conventional socket or nut driver. Use a piece of sticky
tape inside the socket to prevent the loose orifice from
falling out.
Verify that the orifice sizes in the kit match the chart sizes and
replace the burner orifices. Both the main and simmer orifices
must be changed. Do not reassemble the burners at this time.
NATURAL GAS
LOCATION
SIZE
MARKING
CENTER
1.85mm
OUTER
1.78mm
LP GAS
LOCATION
SIZE
MARKING
CENTER
1.10mm
OUTER
1.10mm
MAIN
RATE
SIZE
185
17.5K Btu/hr 0.57mm
178
16.0K Btu/hr 0.57mm
MAIN
RATE
SIZE
110
15.0K Btu/hr 0.37mm
110
15.0K Btu/hr 0.37mm
Burner Head
(Brass)
Burner Ring
(Aluminum)
Locator Pin
Burner Base
Simmer Orifice
4mm
LOW
MARKING
RATE
P
3400 Btu/hr
P
3400 Btu/hr
LOW
MARKING
RATE
G
2900 Btu/hr
G
2900 Btu/hr
2
Burner Cap
Burner Ring
Locking Nut
Electrode
Main Orifice
7mm