Emerson Fisher 2625 Руководство по эксплуатации - Страница 5
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Промышленное оборудование Emerson Fisher 2625. Emerson Fisher 2625 12 страниц. Volume boosters
Также для Emerson Fisher 2625: Руководство по эксплуатации (16 страниц)
Instruction Manual
D100348X012
The booster may also be directly mounted to the actuator by using an actuator yoke mounting bracket (see figure 5)
or casing mounting bracket.
Pressure Connections
The input signal connection is 1/4 NPT. The supply and output connections are 3/4 NPT (minimum pipe size
recommended for nipple mounting is 1/2 NPT). Connections to the volume booster should be made as indicated in
figure 3. Connections for two typical applications are shown in figure 2. Ensure that the piping is of proper size to meet
the capacity demands of the booster and that you equip the actuator with properly sized input connections.
Figure 2. Typical Installations
POSITIONER
INPUT SIGNAL
ACTUATOR
PIPE TEE
PIPE BUSHING
BODY
BODY PROTECTOR
OPTIONAL
DIAGNOSTIC
CONNECTION
B2372‐1
POSITIONER OUTPUT
(TOP CYL)
PIPE NIPPLE
PIPE TEE
PIPE BUSHING
BODY
BODY PROTECTOR
WITH A PISTON ACTUATOR
WITH A DIAPHRAGM ACTUATOR
OPTIONAL
DIAGNOSTIC
CONNECTION
2625 OR 2625NS
VOLUME BOOSTER
PIPE NIPPLE
POSITIONER
ACTUATOR
2625 and 2625NS Volume Booster
2625 OR 2625NS
VOLUME BOOSTER
SUPPLY
67D, 67DR,
OR 95H
2625 OR 2625NS
VOLUME BOOSTER
POSITIONER OUTPUT
(BOTTOM CYL)
POSITIONER OUTPUT
SIGNAL
SUPPLY
67D, 67DR, OR 95H
January 2015
5