Keypad Functions
The keypad on the rear of the unit provides the installer access to:
Listen to the current IP address or reset it to a default IP and subnet MASK address. Make test
calls and control speaker level during the call.
Get current IP address;
During standby, press 'C' on the rear keypad to retrieve the current IP address.
The address will continue to repeated, press 'D' to end the cycle and return the unit to
standby mode.
Resetting the IP address
To reset the address, connect the power (via the power jack or Ethernet PoE lead).
Wait about 10-20 seconds,
then enter *# *# 7*1, this will set address mode to Static the IP address to 192.168.1.100,
set the subnet mask to 255.255.0.0 and clear the Administration Password.
OR enter *# *# 7*2, this will set address mode to Dynamic IP and also clear the admin
password.
Making a test call.
To test if the unit has been successfully registered, press 'D' to loop the line, then dial the
number required plus #. If all is well, a connection will be made.
Press D again to go off line. If the line is engaged or the other party hangs up the unit will
automatically disconnect.
Calling a phone by its IP address can be done by entering a * between each group of digits
and the port number. IE, if a phone you wish to call is on IP 192.168.1.117:5060, type
D 192*168*1*117*5060 #. (note not all phones can be called using this technique).
If the default port is 5060 for the remote phone, then it may not be required when calling.
Volume control 'B' & 'C'
During conversation, the speaker volume may be increased by pressing B or decreased by
pressing C. These adjustments only remain as set for the duration of the call and do not
affect the default level.
To set the default level refer to System Settings on page 11.