Agrowtek AXG Руководство по эксплуатации - Страница 4

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Система безопасности Agrowtek AXG. Agrowtek AXG 6 страниц. Strobe-horn alarm module

Purge Switch Connection

A push button switch is available from Agrowtek Inc. or users can provide their own to connect to the AGX
alarm module switch input terminals. The push button contact must be "normally closed" when in the un-
pressed position. When activated, the input will activate speci c operations in the GCX control system to
purge the environment of excess carbon dioxide levels.
The switch terminals provide +5Vdc and a sinking input to detect the switch condition.
NOTICE
A jumper is required to bypass the purge switch if it is not installed, or the input detection can be inverted/
disabled by momentarily pressing the reset button with a pin.

Horn Tone Switches

Multiple horn tone options and intensity levels are available by con guring the DIP switches beneath the
cover bezel. Remove the cover bezel by prying outward from the center of the bezel at the bottom.
IMPORTANT
Switches 1 & 2 must always be set at factory position: 1 = OFF, 2 = ON.
Modifying switch positions 1 or 2 can prevent the unit from operating correctly.
M ech anical Temporal 3
M ech anical - Continuous
2 40 0 H z - Temporal 3
2 40 0 H z - Continuous
Ch ime - Temporal 3
Ch ime - Continuous
W h oop
W h oop
Switch position 6 sets the horn output: ON = High DBA, OFF = Low DBA
Factory switch positions shown in the graphic above. The dark area represents the switch knob.
4
H O RN TO N E
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
S W ITCH PO S ITIO N
3
4
5
O N
O N
O N
O F F
O N
O N
O N
O F F
O N
O F F
O F F
O N
O N
O N
O F F
O F F
O N
O F F
O N
O F F
O F F
O F F
O F F
O F F