Coral Coral Series Руководство по установке и эксплуатации - Страница 4

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Диспенсер для воды Coral Coral Series. Coral Coral Series 15 страниц. Cabinet

Connecting the Softener.
Once you have completed the installation of the valves set the valves as follows:
Softener Inlet and Outlet valve
CLOSED Bypass valve OPEN
You can now safely return the stop cock to the open position. Using the hoses
provided (if installation kit ordered) connect the straight end of the hose having
first inserted the washer provided to the softener inlet and outlet valves.
Connect the angled end to the Softener. The Softener inlets and outlets should
be indicated either with the words inlet or outlet or with an embossed
directional arrow on the Softener tails. Normally the Softener tails are in a
configuration of three with the centre normally being the waste outlet.
Waste Pipe Installation.
Connect the waste pipe to the waste outlet on the Softener and run the hose to
either an up stand or outside drain, a minimum air gap of 20mm must exist at the
end of the drain line. Softened water will have no adverse effect on a septic tank.
Should you need to extend the drain hose this can be done by connecting to a
15mm copper tube for a maximum run of 8 meters with a minimum daytime
pressure of 40 psi. Ensure that the drain hose is not kinked or obstructed in any
way as this will lead to an overflow of the softener. The drain pipe can run
uphill to a maximum of 1 Meter with a minimum water pressure of 40 psi.