Bracket Installation
Adjust the tank bracket so that it
hangs on the outside of the aquarium.
RANGE OF THE CLAMP
PULL-OUT
PULL-OUT
PLACE ON
AQUARIUM
Once step 2 is finished, snap the main
body into the bracket indicated by a
"click". Snap the other bracket with the
suction cup in the same way.
SNAP-IN
For horizontal positioning,
take the suction cup out
and snap the main body
into the brackets until it
locks with a "click".
UV Lamp installation
Remove threaded-cap, install UV lamp
into socket until lamp "clicks" into place.
Slide the Turbo-Twist bracket onto the tank
bracket. Make sure the Turbo-Twist bracket
is securely fastened onto the tank bracket.
TURBO-TWIST
BRACKET
TANK
BRACKET
SNAP-IN
SUCTION CUP
SNAP-IN
SNAP-IN
THREADED-CAP
UVC LAMP
Make sure that the flat O-ring gasket is properly positioned
inside the threaded-cap (already installed in unit). Screw
the threaded-cap tightly back into place.
O-RING GASKET
Attaching the hose lock nuts
Position the hose lock nuts
on the hose-barb inlet/outlet.
HOSE LOCK NUT
Hose barb adapter installation
Place the O-ring on
Hand tighten the hose
hose barb inlet/outlet.
barb adapter onto the
Turbo-Twist.
O-RING
HOSE BARB ADAPTER
Note: Water will leak if the O-ring is not in place.
Installing
the Turbo-Twist
Hang the unit using
the Turbo-Twist
bracket and suction
cup on the outside
of the aquarium.
Adjust the tank
bracket to secure
the Turbo-Twist
UV Sterilizer.
AQUARIUM
Note: The plug and cord
should be turned together
when screwing the threaded-
cap back into place.
Use flexible tubing to connect the sterilizer
to the water supply. Turn the hose lock nut
counter-clockwise to tighten flexible tubing
onto the hose barb. Hose lock nuts require
only hand tightening.
Note: Do not
use O-ring when
larger hose barbs
are being used.
Use flexible tubing to connect
the sterilizer to the water supply.
Turn the hose lock nut counter-
clockwise to tighten flexible
O-RING
tubing onto the hose barb.
FLEXIBLE
TUBING
SMALL HOSE LOCK NUT
Horizontal Positioning
Attach Turbo-Twist bracket with screws on
a fixed surface.