Galvin Engineering galvinspecialised Flowmatic TZ-FLOWTAPC24 Краткое руководство по эксплуатации - Страница 4

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Блок управления Galvin Engineering galvinspecialised Flowmatic TZ-FLOWTAPC24. Galvin Engineering galvinspecialised Flowmatic TZ-FLOWTAPC24 4 страницы. Automatic 24ac concealed wall assembly for basins and troughs

Maintenance Instructions:
Solenoid Valve – (Supplied with own instructions)
1. Turn the water supply off.
2. Activate the sensor to drain as much water from the installation
as possible.
3. Turn the power off at the GPO.
4. Remove the power plug from the solenoid.
5. It may be more convenient to remove the solenoid valve
completely from the installation to service it.
6. Remove the top nut and pull off the coil.
7. Remove O-ring and black valve cover.
8. Unscrew the 4 screws and carefully pull plunger assembly
from the valve body.
9. Separate the plunger tube from the diaphragm.
10. Be careful to retain all springs from inside the solenoid.
11. Wash the diaphragm in clean water and ensure the bleed hole
is clear of any debris.
12. Please take note of the location of the components and
reassemble in the correct order.
13. If the solenoid was removed from the line it may now be
replaced.
14. Push the power plug from the sensor back onto the solenoid.
15. It is recommended that the line strainer be serviced and
cleaned at this stage to ensure that dirt and grit isn't restricting
the flow.
16. Turn power on and test the tap.
Sensor
The Electronic Sensor is a non-serviceable product. If damaged,
the sensor must be replaced.
1. Turn power off at GPO.
2. Unscrew the two fixing screws. The silicon seal may have to
be cut with care.
3. Unplug the solenoid plug and transformer plug from the rear
of the sensor. Generally, if the sensor has been damaged by
an electrical surge, it is recommended that the transformer be
replaced at the same time.
4. Replace the sensor and reconnect the new sensor.
Plug the solenoid and transformer plugs back onto the rear
of the sensor. Fix the sensor panel back onto the galvanised
inwall box with the existing screws.
5. IMPORTANT: Seal the stainless steel face panel and screws
using silicon, ensuring it has a water tight seal.
410 Victoria Rd, Malaga, WA 6090
1300 514 074
Within Australia:
Outside Australia:
+61 (0)8 9249 5916
Fax:
Email:
www.galvinengineering.com.au
ABN: 78 008 719 382
© Galvin Engineering Pty Ltd: 2015 (Issue 12/2015)
+61 (0)8 9249 5900
PERTH I SYDNEY I MELBOURNE I BRISBANE I ADELAIDE
Flowmatic
®
Transformer
The Transformer is a non-serviceable product. If damaged the
transformer must be replaced.
1. Turn power off at GPO and unplug the transformer.
2. The transformer comes standard with 3 metres of cable.
3. Determine if cable access is difficult or if the cable is fed
through a conduit. If the cable is in a conduit then a lead or
leads may be required to be tied to the existing cable before
it is removed so the new cable can be pulled back through.
4. Remove the transformer and cable.
5. With the new transformer in place feed the cable back to the
Control Module and plug in the appropriate plug connector.
6. Plug the transformer into the GPO point.
7. Turn on the power to the unit and test
Warranty:
Galvin Engineering warrants each product to be free from
defects in material and workmanship under normal usage for
a period of one year from the date of original shipment. In
the event of such defects within the warranty period, Galvin
Engineering will, at its option, replace or recondition the
product without charge.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY
AND IS THE ONLY WARRANTY GIVEN BY THE GALVIN
ENGINEERING
WITH RESPECT TO THE PRODUCT.
GALVIN ENGINEERING MAKES NO OTHER WARRANTIES,
EXPRESS OR IMPLIED. GALVIN ENGINEERING HEREBY
SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
The remedy described in the first paragraph of this warranty
shall constitute the sole and exclusive remedy for breach
of warranty, and the Company shall not be responsible for
any incidental, special or consequential damages, including
without limitation, lost profits or the cost of repairing or
replacing other property which is damaged if this product does
not work properly, other costs resulting from labor charges,
delays, vandalism, negligence, fouling caused by foreign
material, damage from adverse water conditions, chemical, or
any other circumstances over which Galvin Engineering has
no control. This warranty shall be invalidated by any abuse,
misuse, misapplication, improper installation or improper
maintenance or alteration of the product
A business unit of
Specialised commercial taps and valves
Electronic Tapware & Control Valves