Mounting Hole Dimension Check
The proper fit between the pressure probe and mounting well must
be maintained throughout the service life of the gauge and should be
checked periodically. A gauge plug (P/N 200908 - Figure 3) is
available which can be used to check the hole as follows:
1. Referring to Figure 4, paint the clean dry surfaces of the gauge
plug as shown with machinists ink, such as Dykem steel blue
(Note 1).
2. To prevent galling, lubricate the threads with a high temperature
anti-seize compound.
3. Insert the plug and torque lightly until seated in the well.
4. Remove and carefully examine the plug. Except for the 45°
chamfered surface, the Dykem should be intact. If marred, it is an
indication of some type of mechanical interference which must be
corrected before the transducer is installed.
5. Typical interference problems are:
Burrs or chips in the hole ............................... Remove
Undersized dimension .................................... Remachine
Eccentric threads/hole ................................... Remachine
Poor surface finish .......................................... Remachine
Frozen plastic on seating surfaces ................... Remove
Frozen plastic in hole ...................................... Remove