Main Combi 24 HE Руководство пользователя и важная информация о гарантии - Страница 4
Просмотреть онлайн или скачать pdf Руководство пользователя и важная информация о гарантии для Котел Main Combi 24 HE. Main Combi 24 HE 12 страниц. Wall mounted combination boiler gas fired central heating unit
Также для Main Combi 24 HE: Руководство пользователя (12 страниц)
A
Fast Flashing (2 every second)
B
Slow Flashing (1 every 2 seconds)
C
Slow Flashing (1 every 2 seconds)
Slow Flashing (1 every 2 seconds)
D
Slow Flashing (1 every 2 seconds)
E
Reset Position
4
Off
On
Off
On
On
On
On
Off
On
On
Reset
Fault Indication
1. Your Main Combi 24 HE has three neon
indicators. The upper two function as boiler on and
fault indicators.
Burner On
2. Depending on the nature of the fault the upper two
Flame Failure
neons will illuminate, go off or flash.
Power On
3. There are five possible combinations, each
indicating one or more fault conditions. These are
described below.
A
The flue or flue terminal is blocked or obstructed in
Burner On
some way, or there is an internal fault.
Flame Failure
If there is no external blockage of the flue that can be
Power On
easily removed contact your Installer or Service
Engineer.
B
The circulating pump is faulty or the system pressure
has dropped. Check the system pressure (see page
7). If the pressure is in the normal range a pump fault
Burner On
is indicated. Contact your Installer or Service
Flame Failure
Engineer.
Power On
C
A fault on the boiler temperature sensor is indicated.
Contact your Installer or Service Engineer.
D
The primary system or the boiler has overheated.
Burner On
Allow the boiler to cool. Turn the selector switch fully
anti-clockwise against the spring pressure to the
Flame Failure
'Reset' position and hold for at least 2 seconds.
Power On
If this occurs repeatedly contact your Installer or
Service Engineer.
If the boiler does not relight after resetting it is
possible that the flue has overheated. Contact your
Installer or Service Engineer.
Burner On
E
Flame Failure
The burner has failed to light, or incomplete lighting
Power On
of the burner has occurred. Turn the selector switch
fully anti-clockwise against the spring pressure to the
'Reset' position and hold for at least 2 seconds.
If this occurs repeatedly contact your Installer or
Service Engineer.
If the boiler does not relight after resetting blockage
of the condensate drain or trap has occurred.
Contact your Installer or Service Engineer.