Corbin Russwin Access 800 Руководство по установке - Страница 11

Просмотреть онлайн или скачать pdf Руководство по установке для По замкам Corbin Russwin Access 800. Corbin Russwin Access 800 16 страниц. Cl33800 tcac2 series cylindrical lockset
Также для Corbin Russwin Access 800: Руководство по установке (17 страниц), Инструкция по программированию (16 страниц)

Corbin Russwin Access 800 Руководство по установке

5) Installation of RF Technology Lock

The RF Technology Lock (M804, M805, M806) is installed as described in
11
section 4 with the following exceptions:
Installation of the top through-bolt screw
Removal procedure for the battery keeper
1. Installation of the top through-bolt screw:
The antenna board must be carefully moved to access the upper through-bolt screw. Care
should be taken to prevent damage to the antenna retaining tabs during this process.
Press the two tabs away from the antenna board and lift the board off the mounting posts.
Insert the oval head through-bolt and secure the escutcheon in place. After tightening the top
through-bolt, replace the antenna board by placing it on the mounting posts and pressing into
the retaining tabs.
2. Removal and Installation Procedure for Battery Keeper
To remove the battery keeper, a flat blade screwdriver or similar tool must be used.
Insert screwdriver into slot at top of battery keeper. Lift up and pull the top of the keeper
away from the batteries.
To install the battery keeper insert bottom tabs in bottom slots of controller, then press keeper
over batteries and snap into position.
Retaining Tabs
Flathead thru-bolt
* Use screw with painted head
Failure to do so will result in damage to electronics
Antenna
circuit
board
Mounting Posts
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
10
Battery Keeper
Screwdriver slot
Bottom Slots
TEST
FOR PROPER
OPERATION
BEFORE
CLOSING
DOOR