Dea SWINGER Инструкции по эксплуатации и предупреждения - Страница 4
Просмотреть онлайн или скачать pdf Инструкции по эксплуатации и предупреждения для Открыватель ворот Dea SWINGER. Dea SWINGER 13 страниц. Electro-mechanical operator for swing gates
Также для Dea SWINGER: Руководство по эксплуатации (20 страниц)
2 PRODUCT DESCRIPTION
Models and contents of the package
With the name GEKO is identified a series of operators for the automation of swing gates and doors of medium and small size. All mo-
torized models, involve the use of advanced control units (NET series) equipped with anti-crushing sensor, 433 MHz radio receiver, speed
control and slowdown in opening and closing.
GEKO models are designed for residential/collective semi-intensive use, according to the duty cycle of this operator.
Complementary accessories are shown in the table "PRODUCT ACCESSORIES" (p. I-4).
GEKO is an electromechanical operator essentially constituted by a gear motor that rotates an articulated arm (or sliding arm); this
arm is attached to the leaf to be moved.
Inspect the "Contents of the Package" (Pic. 1) and compare it with your product for useful consultation during assembly.
Transport
GEKO is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.
3 TECHNICAL DATA
Motor power supply (V)
Capacity (W)
Max torque (Nm)
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour
Operating temperature range (°C)
Opening time 90°(s)
Sound pressure emitted (dBA)
Product weight with package (kg)
Protection degree
Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
Flashing light output
Receiver frequency
Transmitters type of coding
Max remote controllers managed
OPERATOR
24 V
80 W
180 Nm
20
60
-20÷50
16
<70
12
IP44
CONTROL BOARD
230 V ~ ±10% (50 Hz)
120 VA (230/22V)
2A
2x 12V 1,3A
15A
2x 5A
24 V
(24V_AUX + 24V_ST = max 200mA)
+24 V
max 15 W
24V
max 5W oppure max 1 art. 110
24 V
max 15W
433,92 MHz
HCS fix-code - HCS rolling code - Dip-switch
100
EN-3