8.6 LED indicator

Operating states are indicated over the LED.
Status LED indicators
Modulstart INIT
Once when applying the operating voltage
Standby
During operation with switched off channel
Output Switched On
Switched on, the brightness of the LED depends on the output level
Receive bus event
DMX-telegram received
Operation via push button input
DMX input button is pressed, mains voltage is present
Programming mode
DMX identification display; ready for load calibration
Error 1
Switching off outputs due to overload.
Error 2
Reduction of output level due to overload.
Fatal Error
Shutdown due to overload or overtemperature
Measuring procedure
Performing calibration with dimming mode
Corridor function activated
If the corridor mode is activated

8.7 Appendix - Symbols

Symbols / legend
Connected load
ON = full brightness
Connected load
dimmed
Connected load
OFF = Off
Device LED
ON = full brightness
Device LED
LED - dimmed
Device LED
OFF = Off
Load type with leading edge
Load type with trailing edge
Device button
External push button input
Time for a key press
in this case, press the button for more than 2 sec.
www.maintronic.de
Blinking pattern approx. 3 sec.
0s
1,5s
3s
OOOOOOOOOO----------
O-------------------
OOOOOOOOOOOOOOOOOOOO
O-O-----------------
OOOO-OO-------------
OOOOO-----OOOOO-----
O-O-O-O-O-O---O-----
O-O-O-O-O-O---O-O---
O-O-O-O-O-O-O-O-O-O-
O--O--O--O--O--O--O-
OOOOOOOO--OOOOOOOO--
17