MIEN2016/2018/2024/2026 Rack Mount Industrial Ethernet Switch
Before laying the cable, check whether the cable is damaged, whether
there are factory records and quality assurance certificates that prove its
quality
The specifications, quantity, routing direction, and location of the cables
to be laid should meet the design requirements of the construction drawing,
and the wiring length of each cable should be determined according to the
actual location
User cables and power cords are laid separately
There must be no broken wires or joints in the middle of the laid cables
The cables should be laid out neatly in the aisle, and the bends should
be even, smooth and straight
The cable should be straight in the channel, and should not go out of the
channel and block other cable entry and exit holes. The cable should be tied
and fixed at the location of the cable exit from the channel or the cable bend.
When the cables, power cords, and ground wires are laid in the same
slot, the cables, power cords and ground wires cannot be overlapped or mixed.
When the cable is too long, the cable must be neatly placed in the middle of the
cable rack, and cannot be pressed on other cables
When laying pigtails, prevent the optical cable from knotting and
minimize the turning points, and the turning radius should not be too small. The
lashing should be moderately tight and not too tight. When laying on the cable
rack, it should be placed separately from other cables
Both ends of the cable should have corresponding marks, and the
content of the marks is concise and easy to maintain
Note:
When laying pigtails, prevent the optical cable from kinking and
minimize the turning point, and the turning radius should not be too small. If
the turning radius is too small, it will cause serious loss of the link optical
signal. Affect the quality of communication.

2.3. Simple test

2.3.1. System self-check

All the service port indicators on the front panel will flash once when the
device is powered on, indicating that the port is working normally. After that, the
corresponding Power will always be on, and the Run light (system running
status indicator) will flash at intervals of 1s.