Adexa HRQ-711 Руководство по эксплуатации - Страница 7

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Печь Adexa HRQ-711. Adexa HRQ-711 13 страниц. Gas solid top with gas oven

Instruction Manual
the exhaust fan should be installed to ensure that the steam and the
combustion exhaust gas are discharged during the work process.
※After the installation of the machine, must keep stable, horizontal
placement can not be tilted, also can not be shaken when used.
※Use the gas with the permission of the gas supplier first, and verify
that the supplied gas is consistent with the gas used in the future.
※Do not use other gas not conforming with the machine as fuel and high
pressure regulator.(This machine is only suitable for using the
low-pressure control valve.)
※The used voltage of the equipment must comply with the rated voltage
(do not use other power sources that do not conform to the machine)
3.2 Connect of the gas
※A quick cut air valve must be installed before installing the machine
and must be located near the machine.
※Make sure the machine is the same type of gas connected. If not, do
not connect because the gas connection pipe is painted yellow.
※The pipes connected to the machine must be connected with suitable
metal pipes.
※The machine shall be tested with LPG.
※If the pipe pressure is 10% higher than the rated pressure required
by the machine, a regulating valve is required to ensure that the rated
pressure is reached.
※After connection, test with soapy water or test whether there is air
leakage at the test pipeline connection, " do not use the fire source
ignition test!"
3.3 Electrical connection
※Users should install appropriate switch, fuse and leakage protection
near the equipment. sundries should not be stacked in front of the switch
to facilitate operation.
※The furnace body is provided with equipotential grounding bolts, and
the wire of not less than 1.5mm 2 copper conductor shall be reliably