Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Symptom
Symptom
Symptom
Symptom
No flow or poor flow
rate.
Water dripping for a few
seconds after the tap
has been turned off.
Constant dripping /
leaking when the tap is
not in use.
Fitting does not turn on.
Water does not come
out of the showerhead
when using the bath
shower mixer.
18
Cause
Cause
Cause
Cause
Partially closed stop or service
valve in water supply pipework to
the tap.
Head of water is below the
minimum distance required.
Possible airlock / blockage in
supply pipework
Valve not opening fully.
This is caused by 'capillary
action' and residual water in the
spout being siphoned out. This
should only last for a couple of
seconds.
seconds.
Valve not fully shutting off.
Water supplies not turned on.
Closed stop or service valve.
Diverter mechanism not fully
open.
Insufficient water pressure /
header height.
Remedy
Remedy
Remedy
Remedy
Open stop or service valve.
Refer to the Specification section
for minimum pressures required.
Remove water supplies from the
fitting and flush the system to
remove any airlocks / debris.
Service fitting. Refer to
maintenance section on page 15-
16.
Service fitting and replace
cartridge / valve. Refer to
maintenance section on page 15-
16.
Check that the water supplies to
the fitting are turned on.
Open stop or service valve.
Open the diverter mechanism
fully by turning the diverter lever.
Refer to the specification section
for minimum pressures required.