Majestic Portofino Руководство по установке - Страница 6
Просмотреть онлайн или скачать pdf Руководство по установке для Сантехника Majestic Portofino. Majestic Portofino 14 страниц. 17- or 24-mm surface wall profiles
Также для Majestic Portofino: Руководство по установке (14 страниц)
Portofino Installation Guide
FRONT
(Door and
In Line Panel)
Temporarily assemble the underframe and place it in
1
position on the floor or tray.
Wall leans IN
The Majestic Shower Company Limited
17 Flitch Industrial Estate, Chelmsford Road,
Dunmow, CM6 1XJ
SIDE
(Return Panel)
Wall leans OUT
10 mm
5 mm
Wall does not lean
0 mm
Wall leans IN
Both sections of the underframe are supplied at maxi-
2
mum length to be cut down on site to accommodate
any lean in or lean out of the wall relative to the floor.
For 24 mm wall profile:
If your wall leans inwards, cut 0-9 mm from the wall
end of the profile; if it leans outwards, cut 9-18 mm. If
the wall is at right angles to the floor or tray, cut 9 mm
from the wall end of the profile.
~10 mm
4
Telephone (0)1279 443644
www.majesticshowers.com
Page 6
Wall leans OUT
18 mm
9 mm
Wall does not lean
0 mm
Tray