9. INSTALLER MENU FOR ADJUSTING CONTROL PARAMETERS
Only Qualified Personnel must access this MENU, because changing the set of parameters
could make the product completely unsuitable for the application.
• To enter this Menu, Press the MENU and DOWN button at the same time for 3 Seconds.
• Scroll through the parameter Codes by pressing the Up and Down buttons.
• To view the current value of the code, and to adjust, press the Menu Key.
• To modify the value, use the Up and Down buttons.
• To save the new value, press the MENU key.
• To exit without saving a new value, Press the ON/OFF button.
• Press the ON/OFF button again to exit the MENU (or wait 60 seconds).
Description
Air Thermostat for Fan Activation
Air Thermostat for SAFETY
Air Thermostat for ALARM
Air Thermostat for FAN SAFETY
Air Thermostat for Valve Opening
Air Thermostat for Valve Closure
Air Thermostat for SERVICE output Activation
Temperature Delta for Proportional management
Hysteresis Thermostat for fan Activation
Hysteresis Thermostat for SAFETY
Hysteresis Thermostat for ALARM
Hysteresis Thermostat for FAN SAFETY
Hysteresis Thermostat for Valve Opening
Hysteresis Thermostat for Valve Closure
Hysteresis Thermostat for SERVICE output Activation
Hysteresis Ambient Thermostat
P01 Fan Speed (minimum)
P09 Fan Speed (ninth)
P10 Fan Speed (maximum)
Delay time for Air Damper closure
Audible alarm suspension time
Time for the Fan Accelerator function
S2 Input Configuration
SERVICE Output Configuration
Enable FAN SAFETY
Enable Air SAFETY
Enable Air ALARM
Enable "Start" Function of Air Damper
NOTE: if you modify UA01, UA09, UA10, the Fan immediately works at the speed you are calibrating, showing the effect
of calibration
Cod.
Min
E01
30
E02
80
E03
100
E04
100
E05
20
E06
20
E07
20
E50
20
IE01
1
IE02
1
IE03
1
IE04
1
IE05
1
IE06
1
IE07
1
Ib01
0
UA01
20
UA09
80
UA10
100
t 06
0
t 07
1
t 08
0
P01
0
P02
0
P03
0
P04
0
P05
0
P12
0
16
Set
Max
U.M.
45
100
[°C]
100
140
[°C]
120
180
[°C]
135
180
[°C]
30
140
[°C]
80
140
[°C]
50
180
[°C]
20
100
[°C]
2
40
[°C]
2
40
[°C]
2
40
[°C]
2
40
[°C]
2
40
[°C]
2
40
[°C]
2
40
[°C]
1
20
[°C]
1
100
[%]
1
100
[%]
1
100
[%]
10
120
[min]
5
60
[min]
2
10
[sec]
0
2
n
0
3
n
1
1
n
1
1
n
1
1
n
0
1
n