 Closing Safety Beams, which will prevent the gate from moving
should anyone be in the path of the gate while closing
 Passive Sensitive Edge to help absorb the kinetic energy of the
gate in the event of a collision and provide additional time for the
inherent electronic anti-crushing technology of the operator to
react. Must be installed on all shearing edges
Additionally, the IRBOC feature must be invoked on the
controller so that the gate will immediately reverse direction,
in the event of a collision, regardless of whether it is
commencing with the opening or closing cycle
8. Lubrication
Do not attempt to run the operator without first filling the
gearbox with lubricant
In order to prevent possible leakage during shipping, the unit is
shipped with no oil inside the gearbox. A bottle containing 80ml of a
special synthetic oil is included with the product, and this must be
introduced before operating the product.
Oil filling
procedure
It is more convenient to
introduce oil before
bolting the unit down, as
shown in the illustration
below. The D10/
D10 Turbo does not
require routine oil
changes. However, in the
event of the unit losing oil
due to stripping down or
mechanical damage, the
correct replacement oil is
Castrol SAF XO 75W-90
synthetic final drive
lubricant
 Remove dipstick from gearbox
 Cut the tip off the nozzle which will allow for the oil to pass
through the nozzle; unscrew the oil bottle cap; remove the
seal from beneath the oil bottle cap; replace the oil bottle
cap onto the bottle and attach the extension tube to the
nozzle
 Fill the gearbox with the oil provided

9. Cabling Requirements

Legend
1.
90V-240V AC mains cable via double pole mains isolator switch
(3 core LNE 1.5mm SWA)
Optional wiring (all cable is multi-stranded):
2.
Intercom cable from motor to dwelling
3.
Intercom cable from motor to entry panel
4.
Safe Close and
Beams
Safe Open:
Safety Beams
8
6
7
2
(3 core 0.5mm )
Closing
Safety Beams
Oil specifications
CENTURION product code:
OIL80ML0X0/H
Castrol SAF-XO 75w-90 Synthetic Final
Drive Lubricant
(n1 + 6 core 0 .5mm )
(n2 0.5mm )
Recommended infrared Safety
2
Passive
sensitive
edge
Opening
5
2
2
8