Centurion R3 Руководство по быстрой настройке - Страница 14
Просмотреть онлайн или скачать pdf Руководство по быстрой настройке для Открыватель двери гаража Centurion R3. Centurion R3 19 страниц. Rotary swing gate operator
Также для Centurion R3: Руководство по быстрой настройке (2 страниц), Руководство по быстрой настройке (17 страниц)
At this moment release the TEST button to select feature
number 2. (L2 will turn off, and L1 will keep on flashing 2 times
and pausing to indicate that feature number 2 is selected).
NOTE: The STATUS of the Feature is not changed yet, the
feature has only been selected to be changed!
If an incorrect Feature is selected, then remove and re-
apply power and repeat the procedure.
To change the STATUS value of a Feature: (IM page 31)
Press and hold the TEST button while monitoring the
STATUS light:
(Continues from above example to set outoclose to ON status).
The L1 light will flash once and pause,
At this moment release the TEST button to give a
STATUS value of 1. The AUTOCLOSE feature has been set to
ON
NOTE: Only after setting the STATUS, would the
AUTOCLOSE be turned ON.
(L2 will come back on, indicating that the STATUS has been
set.)
To change the COUNT value of a Feature: (IM page 31)
Press and hold the TEST button while monitoring the
STATUS light:
After a slight pause, the STATUS light will start flashing
regularly:
At this moment release the TEST button to give a COUNT
value of 10. This could for example be the preflash time.
(L2 will come back on, indicating the COUNT value has
been set).
7
E
XIT
Remove the SET link.
10
Flash (1), Flash (2), Flash (3), Flash (4), Flash (5),
Flash (6) ................ Flash (9), Flash (10).
P
ROGRAMMING
M
ODE