3.4.6 Wi-Fi Communication
The Wi-Fi communication function is only applied to WiFi box, the detailed configuration instruction can be referred to Wi-Fi
Configuration in the accessory box.
Connection Procedure:
● Take out the interior cable of the inverter.
● Insert cable into the WiFi BOX. please refer to Figure 3.4.6-1.
● Lock the
WiFi
BOX onto the chassis tightly.
3.4.7 Power Limiting device installation
Connection method of
Power Limiting device
CT please refer to Figure 3.4.7-1.
1-White wire
CT
2-Black
wire
L
Inverter
POWER
RUN
FAULT
NOTE:After installation is completed, please set up power limiting function referring to section 4.5
11
Figure 3.4.6-1
N
Switch Board
Router
Figure 3.4.7-1
● Pay attention to the direction of CT when wiring. CT clip should be locked tight. White cable should connect Line 6 and black cable
should connect Line 5. Tighten them with screwdriver. Make sure CT cables connected to the right output phase lines of inverter
when in use.
● Without connection of CT, inverter will show "CT Disconnect". If CT is connected reversely, inverter will show "CT Reverse"when
it enters into on-grid status .
2. Connection Procedure:
● Put the cable through the components in this order: screw cap, one-hole sealing ring, insulation body and sheet metal parts.
● Take the green terminal out of accessory bag. cable should be connected as Figure 3.4.7-1.
● Insert the green terminal into the corresponding interior terminal of the inverter. Pull cable softly to maintain the cable not to be
pulled out.
● Lock the sheet metal parts onto the box and tighten the screw cap.
123456
Function
Line
1
CT+
2
CT-
3
Reserved
4
Reserved
5
Digital output
6
Digital output
Figure 3.4.7-2
12