AT
Command
RT
Receiver Threshold
This command sets threshold of receiving
signal which decides on receiver turn-on
during the reduced power consumption
mode. Parameter is expressed in -dBm.
Example: 115 value determines that all
signals above -115dBm should turn the
receiver on, to be received at the same
time. Signals weaker than -115dBm will be
rejected.
Radio modem PRM4 868MHz /User's manual V1.6 / 24.05.2011
Description
Parameter
Default
value
110 – 125
115