3 Technical specifications
3.1 Approvals, conformities
3.2 CAPBs sens AQ: Air quality
®
CAPBs
Failure to follow these instructions can result in death, serious injury
and equipment damage.
-
EMC Directive - 2014/30/EU
-
RoHS Directive - 2011/65/EU
-
WEEE Directive 2012/19/EU
Parameter
Measuring range
CO
eq
2
TVOCeq
Measuring
principle
Measuring
interval
Resolution
CO
eq
2
TVOCeq
Units
Heat-up time:
Operating
temperature
AQ20
450 ... 2000 ppm (relative)
125 ... 600 ppb (relative)
Semiconductor (metal oxide)
Continuous
1 ppm
1 ppb
ppm / ppb
< 6 minutes
0 °C to +40 °C