Electrical connections
TCP/IP with external power supply
GAT Access 6100
1
Power supply
DC supply (see technical data), e.g. via GANTNER GAT Power Supply
SP014/1. The power input is protected against reverse-polarity.
Network
Ethernet, connection via screw terminals.
Recommended cables
Ethernet: min. CAT 5 (STP) for 100 MBit
Ethernet wire colours
Ethernet 10/100 MBit
568A
568B
TX +
green/white
orange/white
TX -
green
orange
RX +
orange/white
green/white
RX -
orange
green
Usage of the fingerprint reader GAT FR 055
The sensor field will light-up red if a finger print must be scanned.
Pay attention that the finger is always pressed vertically onto the sensor
field in order to guarantee an optimal scanning of the finger! Furthermore
the finger should be laid rectangular onto the sensor field and touch the
top edge.
See also the operating instructions of the GAT Access 6100 F.
Correct:
Valid as from July 31
2013 • Technical data subject to modifications without notice!
th
4
DB_GAT-ACCESS6100F--BIO-EN_11.indd • PartNo.: 243526
e.g. GAT Power Supply SP014/1
TCP/IP
Incorrect:
Mains power
Power supply unit
Connection to the device upper part
Attention: The socket for the connection cable between the device back
part and upper part (circle with the lable (1) in the connection figure) must
be clean in order to guarantee a good contact.
Relay output
For activation of devices like turnstiles etc.. the relay contact is of type NO
(maker contact). Please observe the max. permitted switching voltages
and currents (see technical data).
Depending on the connected installation (e.g. turnstile) an additional free-
wheeling diode may be necessary, which is used to limit the switch-on
current. Please read the documentation of the connected installation.
Optocoupler input
Input for status acquisition. For using the input a supply voltage must be
applied. This voltage can be taken from the terminal´s supply or from an
external power source. Please observe the max. permitted input voltages
and currents (see technical data).
Safety instructions
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
e.g. Turnstile