ENGLISH
• The electrical mains terminal is live.
• Make electrical mains terminal free of
voltage.
• Loose and inappropriate plug and
socket connections can make the
terminal overheat.
• Have the clamping connections correctly
installed.
• Use strain relief clamp on cable.
• Follow the connection diagram (it is
located on the underneath surface of the
casting of the hob).
Important!
• You must observe the minimum distances
to other appliances and furniture
cabinets or other units according to
Assembly Instruction.
• If there is no oven beneath the hob insert
a dividing panel at a minimum distance
of 20 mm from the bottom of the hob.
• Protect the cut surfaces of the worktop
against moisture using a suitable sealant
included in the product in fitting bag. The
sealant seals the appliance to the work
top with no gap.
• Do not use silicon sealant between the
appliance and the worktop. Avoid
installing the appliance next to doors
and under windows as hot cookware
may be knocked off the rings when doors
and windows are opened.
• Only an authorized service engineer can
install, connect or repair this appliance.
Use only original spare parts.
Electrical connection
• Before connecting, check that the
nominal voltage of the appliance stated
on the rating plate, corresponds to the
available supply voltage. Also, check the
power rating of the appliance and
ensure that the wire is suitably sized to
suit the appliance power rating (refer to
the "Technical information" chapter). The
rating plate is located on the lower
casing of the hob.
• The appliance is supplied with a
connection cable. This has to be
provided with a proper plug, able to
support the load marked on the
identification plate. To connect the plug
to the cable, follow the recommendation
given in following figure.
Replacement of the connection cable
• The replacement of the connection cable
requires the specific equipment of a
technician. Only an original spare part
able must be used, provided by spare
parts service. The plug has to be fitted in
a proper socket. If connecting the
appliance directly to the electric system,
it is necessary that you install a double
pole switch between the appliance and
the electricity supply, with a minimum
gap of 3 mm. between the switch
contacts and of a type suitable for the
required load in compliance with the
current rules.
• The connection cable has to be placed in
order that, in each part, it cannot reach a
temperature 70 °C higher than the room
temperature. The brown (or black) phase
cable (fitted in the terminal block contact
marked with "L") must always be
connected to the network phase.
16
1
2