IKEA LBZ8C Инструкции по установке и руководство по эксплуатации и уходу - Страница 9

Просмотреть онлайн или скачать pdf Инструкции по установке и руководство по эксплуатации и уходу для Вентиляционная вытяжка IKEA LBZ8C. IKEA LBZ8C 48 страниц. 30" (76.2 cm) range hood

Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines distance "A" and distance "B" from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
¹⁄₂
"
A.
(1.3 cm) for 12
⁷⁄₈
"
3
(9.8 cm) for 15
³⁄₄
"
B. 4
(12.1 cm) for 12
¹⁄₈
"
8
(20.6 cm) for 15
Wall Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring ³⁄₈" (0.9 cm) and 3⁷⁄₈" (9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
2¾"
(7.0 cm)
6¾"
(17.1 cm)
(13.3 cm)
*A
*B
"
(30.5 cm) deep cabinets
"
(38.1 cm) deep cabinets
"
(30.5 cm) deep cabinets
"
(38.1 cm) deep cabinets
Centerline
¹⁄₄
¹⁄₄
5
"
5
"
(13.3 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4¹⁄₄" x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines distance "A" and distance "B" from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for vent.
*From wall, not cabinet frame
¹⁄₂
"
A.
(1.3 cm) for 12
⁷⁄₈
"
3
(9.8 cm) for 15
³⁄₄
"
B. 4
(12.1 cm) for 12
¹⁄₈
"
8
(20.6 cm) for 15
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line distance "A" from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Circular vent opening
*A
*From wall, not
cabinet frame
"
A. 5
(12.7 cm) for 12
³⁄₈
"
8
(21.3 cm) for 15
*A
*B
"
(30.5 cm) deep cabinets
"
(38.1 cm) deep cabinets
"
(30.5 cm) deep cabinets
"
(38.1 cm) deep cabinets
Cabinet
cutouts
"
(30.5 cm) deep cabinets
"
(38.1 cm) deep cabinets
9