Installation Instructions

READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
These instructions cover the basic principles to ensure satisfactory installation of the stove, although detail may need slight
modification to suit particular local site conditions. In all cases the installation must comply with National and European
Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the
stove.
It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in
British Standards BS 8303, BS EN 15287-1:2007 as an alternative means to achieve an equivalent level of performance to that
obtained following the guidance given in Approved Document J.
Please note that it is a legal requirement under England and Wales Building Regulations that the installation of the stove is
either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a
Government approved Competent Persons Scheme. HETAS Ltd operate such a Scheme and a listing of their Registered
Competent Persons can be found on their website at www.hetas.co.uk.
Handling
Adequate facilities must be available for unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of
contact, wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation
then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove, care should be taken to avoid the possibility of personal injury.
Please note:
Any white deposits on the stove joints are caused by humidity reacting with the joint sealant. These deposits
may be brushed off and, if necessary, blackened with a proprietary stove polish.
This stove must not be installed into a chimney that serves any other heating appliance.
Chimney
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate
draught of between 12 Pa and 25 Pa so as to clear the products of combustion and prevent smoke problems into
the room.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top
of the chimney should be satisfactory. Alternatively the calculation procedure given in EN 13384-1 may be
used as the basis for deciding whether a particular chimney design will provide sufficient draught.
Health and Safety Precautions