Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals.
However, if you would like to run a manual defrost cycle at any time, please follow the following
steps: Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
Repeat to stop the defrost cycle.
Defrost System
Refrigerator coils are kept below the freezing point (32°F). During compressor down-time, the
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into
the evaporator pan and evaporated. Freezer coils are defrosted electrically. Automatic defrost timers
automatically initiate at pre-set intervals and for a predetermined duration.