GAPOSA QC100 Руководство по эксплуатации - Страница 13

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Блок управления GAPOSA QC100. GAPOSA QC100 16 страниц. Single-phase control unit

GAPOSA QC100 Руководство по эксплуатации
EMERGENCY MODE WITH
FAULTY BAR
This mode allows the movement of the motor with dead-man control also
in case the optoelectronic bar is active or faulty.
Mode description:
• The mode becomes operational after about 30 seconds from the coast
activation (the count is reset if the bar returns to visibility)
• The mode allows the movement of the motor in opening and closing in
dead-man mode regardless of the position of the dip 2.
• The movement of the motor during this mode is automatically stopped
after 5 seconds. The movement can be resumed by pressing the
command again.
Mode activation:
1. Put dip 6 in ON
2. Move dip 3 at least 3 times from ON to OFF (between two OFF-ON
consecutive steps shall not be more than 2 seconds or the movements
count is reset)
3. If the change is activated, the red and green LEDs will flash quickly for
about 4 seconds
4. Put dip 6 back in OFF
Once the mode activated, it will be actually present only in case dip 3 and
4 are in ON (safety active also in opening and optoelectronic bar active).
Otherwise, the mode is not operational even if enabled.
Mode disabling:
The mode can be disabled exclusively by the reset procedure (see
procedure).