Figure 8
L1 + L2 = 3 m
Total equivalent = 5 m
Figure 9
L1 + L2 + L3 = 3 m
Total equivalent = 5 m
L1
Figure 10
WARNING: Fan baffle plates included in the
package should be used with the connections for
horizontal and vertical flue extensions. Figure 11.
L1
L1
90° elbow = equal to 1 m flue length
45° elbow = equal to 0,5 m flue length
L1
L3
L3
Garanterm Ravi Conventional Combi Boiler Installation and User's Manual
Product
Garanterm
Ravi
HM 24
Garanterm
Ravi
HM 28
12
ELECTRIC CONNECTION
The appliance must be connected to a power supply
line with an efficient earth connection. The appliance
must be connected to 220 ~ 230 V single phase
power supply line with efficient earth connection
through (3-10 A). Automatic circuit breaker.
Figure 11
Total
Equivalent
Air Baffle
Flue Lenght
(mm)
(m)
5
Ø46
4
Ø44
3
Ø42
2
Ø40
5
Ø46
4
Ø44
3
Ø42
2
Ø40
17