KitchenAid Architect II KDRS505XSS Технический паспорт

Просмотреть онлайн или скачать pdf Технический паспорт для Диапазоны KitchenAid Architect II KDRS505XSS. KitchenAid Architect II KDRS505XSS 2 страницы. 30" (76.2 cm) double oven dual fuel range

KitchenAid Architect II KDRS505XSS Технический паспорт
PRODUCT MODEL NUMBERS
KDRS505X
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. See "Gas
Conversions" section. The model/serial rating plate located
behind the control panel has information on the types of gas
that can be used. If the types of gas listed do not include the
type of gas available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See "Gas
Conversions" section.
Gas Supply Line
Provide a gas supply line of
location. A smaller size pipe on longer runs may result in
insufficient gas supply. With LP gas, piping or tubing size can
be
" (1.3 cm) minimum. Usually, LP gas suppliers determine
the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122
to 152.4 cm) long,
" (1.3 cm) or
metal appliance connector may be used for connecting range to
the gas supply line.
A
" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure
regulator.
Do not kink or damage the flexible metal tubing when moving
the range.
Rigid pipe connection:
The rigid pipe connection requires a combination of pipe fittings
to obtain an in-line connection to the range. The rigid pipe must
be level with the range connection. All strains must be removed
from the supply and fuel lines so range will be level and in line.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve.
This valve should be located in the same room but external to
the range opening, such as an adjacent cabinet. It should be in a
location that allows ease of opening and closing. Do not block
access to shutoff valve. The valve is for turning on or shutting
off gas to the range.
B
A
C
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
30" (76.2 cm) Double Oven Dual Fuel Range
" (1.9 cm) rigid pipe to the range
®†
tape.
" (1.9 cm) I.D., flexible
A. Gas supply line
B. Shutoff valve "open"
position
C. To range
PRODUCT DIMENSIONS
A
A.
" ±
" (90.8 ± 0.3 cm)
cooktop height (minimum)
with leveling legs screwed all
the way in
B. Model/serial/rating plates
(located behind the control
panel)*
*** Model/serial/rating plates may be rotated up from behind the control
panel for viewing from the front of the range.
*** Range can be raised approximately 1" (2.5 cm) by adjusting the leveling
legs.
*** Excludes handle. Dimension given is from wall to front of oven door and
will vary based on electric outlet receptacle installation.
ELECTRICAL REQUIREMENTS
To properly install your range, you must determine the type of electrical connection
you will be using and follow the instructions provided for it here.
Range must be connected to the proper electrical voltage and frequency as
specified on the model/serial number rating plate. The model/serial number rating
plate is located behind the control panel. Refer to the figures in "Product
Dimensions" in the "Location Requirements" section.
This range is manufactured with the neutral terminal connected to the cabinet.
Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see following
Range Rating chart). If local codes do not permit ground through the neutral, use
a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for
use with ranges.
Range Rating*
120/240 Volts
120/208 Volts
8.8 - 16.5 KW
7.8 - 12.5 KW
16.6 - 22.5 KW
12.6 - 18.5 KW
** The NEC calculated load is less than the total connected load listed on the
model/serial rating plate.
** If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp
rated cord kits, use kits that specify use with a nominal 1 " (34.9 mm) diameter
connection opening.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
B*
D
E***
F
C.
" ±
" (119.7 ± 0.3 cm)
overall height (minimum) with
leveling legs screwed all the
way in**
D.
" ±
" (72.4 ± 0.6 cm)
depth with handle
E.
" ±
" (66.4 ± 0.3 cm)
F.
" ±
" (76.0 ± 0.2 cm)
width
Specified Rating of Power Supply
Cord Kit and Circuit Protection
Amps
40 or 50**
50
C**
Page 1 of 2
Ref. W10345640B
1/28/11