KitchenAid YKFED500ESS Руководство по установке - Страница 7
Просмотреть онлайн или скачать pdf Руководство по установке для Диапазоны KitchenAid YKFED500ESS. KitchenAid YKFED500ESS 16 страниц. 30" (76.2 cm) freestanding electric range with double ovens
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Add strain relief.
Electrical Connection
Direct Wire
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Style 1: Power supply cord strain relief
■
Assemble a UL listed strain relief in the opening.
■
Feed the power supply cord through the strain relief in the
cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
■
Tighten strain relief screw against the power supply cord.
WARNING
Electrical Shock Hazard
A. UL listed strain relief
A
7