Empire OP36FB2MF-1 Инструкции по установке и руководство пользователя - Страница 6

Просмотреть онлайн или скачать pdf Инструкции по установке и руководство пользователя для Крытый камин Empire OP36FB2MF-1. Empire OP36FB2MF-1 16 страниц. Premium outdoor ventless universal fireboxes

Minimum Wall and Ceiling Clearances (Figure 1)
Sidewall and Back Clearances: The clearance from the
inside of the firebox to any combustible wall should not be
less than 2".
Ceiling Clearances: The ceiling height should not be less
than 36" from the top of the hood.
Mantel Clearances: Ventless firebox models must use the
hood supplied with the firebox. If a combustible mantel is
installed, it must meet the clearance requirements detailed
above.
Do not attach combustible material to the mantel of your firebox.
This is a fire hazard.
Page 6

CLEARANCES

COMBUSTIBLE MATERIALS

Figure 2
Mantel Clearances
12"
10"
MANTEL
COMBUSTIBLES
ALLOWED
27 3/4"
27"
24 1/4"
21 1/2"
18 3/4"
HOOD
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the firebox. This is a heating appliance.
The flow of heat can ignite combustibles.
8"
6"
4"
2"
16"
Figure 1
Figure 3
29083-1-0612