Ceiling Clearances: The ceiling height should not be less than
42 inches from the top of the hood. See Figure 3.
Mantel Clearances: Vent free firebox models must use the hood
supplied with the firebox, or one of the optional hood kits available
for each model. If a combustible mantel is installed, it must meet
the clearance requirements detailed below.
Grate Clearance: The minimum clearance between the front legs
of the grate and front edge of the firebox is 2 inches.
Leave at least 36 inches clearance from the front of the firebox.
CEILING
21"
42" MIN
18 ½"
CEILING TO
TOP OF
HOOD
13"
84"
MIN.
(CEILING TO FLOOR)
8"
MIN.
3/4" COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
Figure 3 - Clearances to Combustibles
39000-2-0820
CLEARANCES
FINISHED
WALL
12"
MAX
10"
MANTEL
10"
COMBUSTIBLES
8"
ALLOWED
6 ½"
16 ½"
5"
14 ½"
3 ½"
12 ½"
2"
10 ½"
3/4"
9"
HOOD
FIREBOX
FACE
WALL
FRAMING
OPEN GAP
Page 5