Jands 4PAK Руководство по эксплуатации - Страница 5

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Контроллер Jands 4PAK. Jands 4PAK 6 страниц. Four channel controller/dimmer

Jands 4PAK Руководство по эксплуатации

Fault finding guide

FAULT SYMPTOM
One channel is not working
Overload circuit breaker trips when
desk channel flashed to full or near
full
Overload circuit breaker trips after
prolonged operation
Overload circuit breaker trips
immediately when channel is driven
One channel flickers when dimmed
Same load flickers on another channel
Radio interference

Technical Data and Specifications

PARAMETER
No. of Channels:
Input Power Requirements:
Output Loading:
Overload Circuit Breaker:
Max Ambient Temp:
Output Risetime:
LED Indicators:
Protection:
Control Law:
Power entry:
Output Connectors:
Size (mm):
Weight:
Ingress Protection
rd
Revision 0
3
December 2003
JANDS
POSSIBLE CAUSE
Faulty load or wiring
Internal channel fault
Large incandescent load
Excessive load
Excessive load
Lamp or wiring fault
Output short
Triac short circuit
Faulty dimmer channel
Insufficient or very inductive load
Faulty EMC component
230 Volts AC Phase-Neutral (220V-240 V ±5%)
Consumption: 10 A maximum
25 W – 2400 W (10 A at 240 V) per channel
2400 W (10 A at 240 V) total maximum
10 A circuit breaker
130µs (2400 W incandescent load, 50% dimmed)
Four Channel levels, Chase, Audio Chase
10 A circuit breaker
PTC transformer protection
Linear RMS output power versus fader control
Output power regulated at 1% change per 2% mains variation
1.8 metre cable with 3-pin 10A plug (Australia only)
1 x 10 A 3-pin Australian Socket per channel (Australia only)
330 (w) x 95 (h) x 250 (d)
- 5 -
REMEDY
Try the same load on a different
channel to confirm.
Workshop service.
Set fader to 5% to preheat lamp.
Reduce channel loading
Reduce channel loading
Check lamps and wiring
Check lamps and wiring
Workshop service
Workshop service
Connect 100W lamp in parallel
Workshop service
4
40ºC
90°C cutout
4 kg nett
IP20
Operating Guide