Jands FP12 Руководство по эксплуатации - Страница 17
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Диммер Jands FP12. Jands FP12 20 страниц. 12 channel, 2.4kva per channel (10a/240v) dimmer rack
Technical Data and Specifications
8.0 Technical Data and Specifications
PARAMETER
No. of Channels:
Input Power Requirements:
3 phase Star only
Maximum Power / Channel
Minimum Power/Channel
Maximum Dissipation
Maximum Ambient Temp
Control Signal
DMX Input
Test Function Level
LED Indicators
Output Protection
Over-temperature cutout
Over-voltage cutout
Ingress protection
Size (mm)
Weight
Rack mounting requirements
Revision 0.1 – 3 June 1999
415 VAC Phase-Phase @ 40A/phase
protected at 50A/phase
Full size neutral required
<24 W/channel (<300 W total)
DMX-512 (1990) Protocol
5 pin AXR male / female
Individual Channels @ 100%
Group Channels @ 10% steps
DMX IN, STATUS,
Phases A, B, and C
12 x 10 Amp thermal/magnetic circuit breakers
Electronic: 83
Mechanical: 90
Average 290VAC
482 (w) x 133 (h) x 250 (d)
3 x 19" rack spaces / standard spacing for mounting holes
Ventilation required at sides of rack
No blank spaces required between units
Power inlet at rear right (looking from front of unit)
Rear access required for patching outputs
FP12 DIMMER
FP12
12
2.4 kW
25W
40ºC
o
o
C rising, 78
C falling
o
C
IP20
16 kg net
8-1
USER MANUAL