Instructions to Installer
1. Installer must leave instruction manual with owner after instal-
lation.
2. Installer must have owner fill out and mail warranty card supplied
with unvented room heater.
3. Installer should show owner how to start and operate unvented
room heater.
Always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of an
unvented room heater.
General Information
This appliance is design certified in accordance with American Na-
tional Standards Institute Z21.11.2 and CR94-001 for use in British
Columbia or Manitoba by the Canadian Standards Association as
an Unvented Room Heater and should be installed according to
these instructions.
Any alteration of the original design, installed other than as shown
in these instructions or use with a type of gas not shown on the
rating plate is the responsibility of the person and company making
the change.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
This appliance is equipped for (natural gas or propane) gas. Field
conversion is not permitted.
16013-6-0314

INTRODUCTION

WARNING

SPECIFICATIONS

Model
Input BTU/HR (KW/H) (LP)
Input BTU/HR (KW/H) (NAT)
Height
Width
Depth
Gas Inlet
Accessories
Blower
Floor Stand
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation, or company that either in
person or through a representative is engaged in and is responsible
for (a) the installation, testing, or replacement of gas piping or (b) the
connection, installation, testing, repair, or servicing of equipment;
that is experienced in such work; that is familiar with all precautions
required, and that has complied with all the requirements of the
authority having jurisdiction.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1
NFPA54.*
*Available from the American National Standards Institute, Inc.,
11 West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be
reduced at the rate of 4 percent for each 1,000 (305m) feet above
sea level. Contact the manufacturer or your gas company before
changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect
the Btu output of the unit. Contact the gas company for the heat-
ing value. Contact the manufacturer or your gas company before
changing spud/orifice size.
BF-10
BF-20
10,000 (2.9)
20,000 (5.8)
10,000 (2.9)
18,000 (5.3)
22" (559mm)
22" (559mm)
18" (457mm)
18" (457mm)
6 1/2" (165mm)
6 1/2" (165mm)
3/8" (10mm)
3/8" (10mm)
SRB-18T
SRB-18T
SRS-18
SRS-18
Page 5