Empire BF-20BC-2 Инструкции по установке и руководство пользователя - Страница 8

Просмотреть онлайн или скачать pdf Инструкции по установке и руководство пользователя для Газовый обогреватель Empire BF-20BC-2. Empire BF-20BC-2 20 страниц. Unvented

When facing the front of the appliance the following minimum clear-
ances to combustible construction must be maintained.
Left side 5 inches (127mm). Right side 5 inches (127mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Minimum vertical clearance from a projection above the appli-
ance (shelves, window sills, etc.) 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches. (51mm)
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provided.
Refer to Figure 4 for measurements in order to locate (4) mounting
holes on wall. Figure 4 is the front view of the heater.
1. Remove lower louver from casing assembly (2 screws).
2. Remove reflector from casing assembly (2 screws).
3. Remove upper louver from casing assembly (2 screws).
On Solid Wall
1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws
provided into the wall. Do not completely tighten screwheads
to the wall, leave a 1/8" (3mm) gap between screwheads and
wall.
2. Mount heater onto the (4) screwheads and complete tightening
screwheads into the wall.
Attention! Use the following steps to properly align the upper
louver and the reflector with the heat shield.
a. When replacing upper louver, be sure the bottom lip of upper
louver goes behind the heat shield.
b. When replacing reflector, be sure the top lip of reflector
goes in front of the heat shield.
3. Connect the gas line.
Page 8

CLEARANCES

WALL MOUNT INSTALLATION

2"
(51)
1 3/32"
(28mm)
OUTLINE OF
OUTER CASING
18 7/8"
(479mm)
2 1/32 (52mm)
4 1/32" MIN
(102mm)
MOUNTING HOLE LOCATIONS
VIEWED FROM FRONT OF HEATER
Figure 3
18"
(457mm)
14"
2"
(356mm)
(51)
2" (51mm)
FLOOR
Figure 4
16013-6-0314
22"
(559mm)