Jandy CL Series Руководство по установке и эксплуатации - Страница 6
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Фильтр для плавательного бассейна Jandy CL Series. Jandy CL Series 16 страниц. Cartridge pool filters
Page 6
Section 3.
Installation Instructions
3.1 Filter Location
1.
Select a well-drained area, one that does not fl ood
when it rains. Damp, non-ventilated areas should
be avoided.
2.
Provide solid mounting for the fi lter and pump
system. Install system on a concrete slab or solid
concrete blocks to avoid risk of settlement. Do not
use sand to level the fi lter as the sand will wash
away. Filter systems can weigh up to 800 lbs.
3.
Install electrical controls at least fi ve (5) feet from
the fi lter. This will allow enough room to stand
away from the fi lter during start-up.
4.
Allow suffi cient clearance around the fi lter to
permit a visual inspection of the clamp ring (see
Fig. 2).
5.
Allow suffi cient space above the fi lter to remove
the fi lter lid and fi lter element for cleaning and
servicing.
6.
Position the fi lter to safely direct water drainage.
Align the air release valve to safely direct purged
air or water.
WARNING
Water discharged from an improperly positioned fi lter
or valve can create an electrical hazard which can
cause death, serious injury or property damage.
CAUTION
Maintain your pressure gauge in good work ing order.
The pressure gauge is the primary indicator of how
the fi lter is operating.
6" MINIMUM CLEARANCE
FILTER
Figure 2.
Filter Location
6" MINIMUM
CLEARANCE
7.
If the fi lter needs to be located above the water
level of the pool, it can be raised 2.5 ft. without
affecting the pump effi ciency. A check valve is
recommended on the suction line to the pump.
8.
If the fi lter is to be installed below the water level
of the pool, isolation valves should be installed on
both the suction and return lines to prevent back
fl ow of pool water during any routine servicing
that may be required.
3.2 Filter Preparation
1.
Check carton for damage due to rough handling
in shipment. If carton or any fi lter components are
damaged, notify carrier immediately.
2.
Carefully remove the accessory package.
3.
A visual inspection of all parts should be made
now. See parts list on page 12.
4.
With the carton in an upright position, remove the
fi lter tank from the carton.
5.
To mount the pressure gauge/air release assembly
to the top of the fi lter tank (located in the accessory
bag):
a.
Place the smaller, thicker o-ring onto the
threads of the tank adapter (see Fig. 3). Slide
the tank adapter through the coupling nut and
into the fi lter tank. Use the fl ats on the tank
adapter to tighten. Do not overtighten.
b.
Place the larger, thinner o-ring onto the gauge
housing. Thread the housing into the coupler
on the tank adapter.
c.
Orient the gauge/air release assembly in the
desired position. Raise and thread the locknut
onto the bottom of the gauge/air release
assembly. Hand tighten the nut only. Using
a wrench to tighten the nut may damage the
nut, gauge or air release assembly.
Figure 3.
Pressure Gauge/Air Release Assembly
Housing
O-Ring
Tank Adapter
Tank Adapter to Housing
Coupler
O-Ring