Section 1. IMPORTANT SAFETY INSTRUCTIONS

1.1

Safety Instructions

All electrical work must be performed by a licensed electrician and conform to all national, state, provincial and
local codes. When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:
EQUIPMENT UNDER PRESSURE: Always turn pump off prior to
installation or service. Your pump/filter system is operated under pressure
and the pressure must be released before you begin work. Please see
your pump/filter owner's manual for further instructions.
To reduce the risk of electric shock, fire or injury, service should
only be attempted by a qualified pool service professional.
Risk of electric shock: When installed as a power source for landscape
lighting: Install power unit 5 feet (1.5 m) or more from a pool or spa and 10 feet
(3.05 m) or more from a fountain. Where the power unit is installed within 10 feet
(3.05 m) of a pool or spa connect power unit to a GFCI protected branch
circuit. Canadian installations must be at least three (3) meters from the water.
Risk of electric shock which can result in serious injury
or death: Before attempting to install or service, ensure that all power
to the circuit supplying power to the system is disconnected or turned
off at the circuit breaker. All wiring must be done in accordance with the
National Electrical Code
(NEC)
®
680 - Swimming Pools, Fountains, and Similar Installations.
In Canada, the Canadian Electrical Code (CEC), CSA C22.1, must be
followed. All applicable local installation codes and regulations must be
followed.
ATTENTION: This power center and the chlorine generator control
center are not to be considered as suitable for use as service equipment.
Therefore, it is required to have the appropriate means of disconnection,
circuit isolation, and/or branch circuit protection installed upstream of the
power/control center
To reduce the risk of injury do not permit children to use this product
unless they are closely supervised at all times
Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure
that children cannot use a spa or hot tub unless they are closely
supervised at all times
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
PREVENT CHILD DROWNING: Do not let anyone, especially small
children, sit, step, lean or climb on any equipment installed as part of your
pool's operational system. Locate the components of your operational system
at least 1 m (3 ft 3 in) from the pool so children cannot use the equipment to
access the pool and be injured or drown.
|
Installation & Operation Manual
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
WARNING
WARNING
, NFPA-70
, including those in Article
®
®
WARNING
WARNING
SAVE THESE INSTRUCTIONS
To reduce the risk of injury, do not remove the suction fittings of your spa or hot
tub. Never operate a spa or hot tub if the suction fittings are broken or missing.
Never replace a suction fitting with one rated less than the flow rate marked on
the equipment assembly.
WARNING
To avoid injury ensure that you use this control system to control only
packaged pool/spa heaters which have built-in operating and high limit
controls to limit water temperature for pool/spa applications. This device
should not be relied upon as a safety limit control. Water temperature in
excess of 100°F (38°C) may be hazardous to your health.
WARNING
A terminal bar marked "GROUND" is provided within the power center.
To reduce the risk of electrical shock, connect this terminal bar to the
grounding terminal of your electric service or supply panel with a continuous
copper conductor having green insulation and one that is equivalent in
size to the circuit conductors supplying this equipment, but no smaller than
no. 12 AWG (3.3 mm2). In addition, a second wire connector should be
bonded with a no. 8 AWG (8.4 mm2) copper wire to any metal ladders,
water pipes, or other metal within five (5) feet (1.52 m) of the pool/spa. In
Canada, the bonding wire must be minimum 6 AWG (13.3 mm2).
WARNING
Install only on a branch circuit protected by a ground fault circuit interrupter
(GFCI), Class A GFCI in Canada. The conductors on the load side of
the ground-fault circuit-interrupter shall not occupy conduit, boxes, or
enclosures containing other conductors unless the additional conductors
are also protected by a ground-fault circuit-interrupter. Refer to local codes
for complete details.
CAUTION: This device is intended for use with permanent swimming
pools and may also be used with hot tubs and spas if so marked. Do not
use with storable pools. A permanently-installed pool is constructed in or on
the ground or in a building such that it cannot be readily disassembled for
storage. A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity.
Modifications made to this equipment, which are not authorized by the
manufacturer, may void the user's authority to operate this equipment.
WARNING
To reduce the risk of FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when turning on.
Do not touch hot lens, guard, or enclosure (see diagram/picture). Keep
lamp away from materials that may burn. Do not touch the lamp at any
time. Use a soft cloth. Oil from skin may damage lamp. Do not operate
the luminaire fitting with a missing or damaged shield.
Lighted lamp is HOT!