Gardena 1483 Руководство по эксплуатации - Страница 3

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос Gardena 1483. Gardena 1483 18 страниц. Pressure tank unit electronic plus with dry-running safety
Также для Gardena 1483: Руководство по эксплуатации (19 страниц)

Gardena 1483 Руководство по эксплуатации
GARDENA Pressure Tank Unit electronic plus
with Dry-Running Safety
4000 /4, 4000 / 5, 5000 /4, 5000 / 5 Inox
Welcome to the Garden of GARDENA ...
Where to Use Your Pressure Tank Unit
Intended use
Liquids to be pumped
Please note
Temperature of the liquid
A

Safety instructions

Use of pump near
swimming pools
Mains power cables
Translation of the original instructions from German. Please read
these operating instructions carefully and observe the notes given.
Use the instructions to familiarise yourself with the equipment, the
operating controls, their correct use, and the notes on safety.
For safety reasons, children under 16 as well as persons not
A
familiar with these operating instructions should not use this
Pressure Tank Unit.
Keep these operating instructions in a safe place.
GARDENA Pressure Tank Units have been designed for private
use around house and garden. Pressure Tank Units are pre-
dominantly used for operating watering implements and systems
in private gardens.
The GARDENA Pressure Tank Units can be used for pumping
rainwater, tap water or chlorinated swimming pool water.
GARDENA Pressure Tank Units are not designed for
A
continuous operation (e.g. industrial application, continuous
circulating operation). Corrosive, easily combustible, aggressive
or explosive substances (e.g. petrol, petroleum, nitro thinner)
as well as food must not be pumped.
The temperature of the liquid to be pumped should not exceed
35 °C.
Pursuant to DIN VDE 0100 -702 and 0100 -738 use of the pump
nearby swimming pools and garden ponds and other similar
places is only permissible, if the pump is operated with a
residual-current device with a residual-current rating ≤ 30 mA.
The pump must not be operated when there are persons in the
swimming pool or garden pond. The pump must be located on
solid, even ground, protected from flooding. Take care that the
pump cannot fall into water.
➔ Please ask your electrician for his advice.
Mains power cables should not have a smaller cross-section
than a rubber sheathed cable of the designation H07 RNF.
Extension cables must meet the requirements of DIN VDE 0620.
15